Skip to main content

Table 4 The computed results of the flux connectivity constraints for Case II

From: Estimating parameters for generalized mass action models with connectivity information

Without flux connectivity constraints

With flux connectivity constraints

No.

noise-free

5% noise

noise-free

5% noise

1

4.735E-1

5.392E-1

5.499E-5

3.573E-3

2

-1.742

-1.785

-3.055E-5

-8.999E-4

3

1.231E-1

1.375E-1

6.428E-5

-2.474E-4

4

1.720

1.745

-2.078E-6

1.351E-3

5

-4.973E-1

-5.237E-1

1.404E-5

-1.694E-3

6

5.514E-1

4.366E-1

1.852E-4

-2.283E-3

7

-1.394

-1.336

-4.564E-5

6.405E-4

8

5.378E-1

5.177E-1

-2.719E-5

1.319E-4

9

1.241

1.209

1.303E-4

-8.199E-4

10

-3.540E-1

-3.401E-1

-1.360E-4

1.042E-3

11

3.681E-1

3.208E-1

-1.211E-4

-1.929E-3

12

-2.213

-2.267

-9.843E-6

3.888E-4

13

-4.378E-1

-4.162E-1

1.878E-4

-6.744E-5

14

2.367

2.411

-1.812E-4

-4.822E-4

15

-6.911E-1

-6.132E-1

2.170E-4

5.719E-4

  1. "Noise-free" indicates that the measured flux control coefficients are perfect, while "5% noise" is based on measured flux control coefficients with 5% uncertainty.