Skip to main content

Table 5 The results in the ISB test data with the SVM classifier for triply charged spectra

From: Quality assessment of tandem mass spectra using support vector machine (SVM)

Times

FP

FN

TPR (%)

TNR (%)

1

2120

24

91.2

87.7

2

2091

15

94.5

87.8

3

2195

12

95.6

87.2

4

2324

19

93.0

86.5

5

2029

26

90.5

88.2

6

1952

23

91.6

88.6

7

2163

12

95.6

87.4

8

2350

19

93.0

86.3

9

1967

20

92.7

88.5

10

1994

21

92.3

88.4

11

2071

17

93.7

87.9

12

1948

21

92.3

88.7

13

2163

26

90.5

87.4

14

1998

26

90.5

88.4

15

2162

23

91.6

87.4

16

2101

16

94.1

87.8

17

2005

21

92.3

88.3

18

2161

20

92.7

87.4

19

1930

28

89.7

88.7

20

2134

17

93.8

87.6

Ave.

2093

20

92.7

87.8

SD

118.3

4.6

1.67

0.69