Skip to main content

Table 4 Cell cycle classification accuracy for a dataset of 4606 samples derived from the syncytial blastoderm stage using weighted-SVM and 9 features. (Pred. = predicted)

From: Cell cycle phase classification in 3D in vivo microscopy of Drosophila embryogenesis

  Pred. Inter Pred. Pro Pred. Meta Pred. Ana Pred. Telo True Total Accuracy
True Inter 2293 87 3 4 59 2446 93.7%
True Pro 20 306 32 0 1 359 85.24%
True Meta 7 20 755 19 0 801 94.26%
True Ana 5 0 32 313 26 376 83.24%
True Telo 15 0 1 19 589 624 94.39%
Pred. Total 2340 413 823 355 675 4606 92.40%