Skip to main content

Table 3 Statistical differences between automatic and manual architectural features

From: Cascaded discrimination of normal, abnormal, and confounder classes in histopathology: Gleason grading of prostate cancer

Class

p > 0.05

p > 0.01

Epithelium

13

17

Stroma

24

26

Grade 3

6

9

Grade 4

11

15

Grade 5

28

29

  1. Number of architectural features whose values were considered statistically similar between automatically- and manually-detected nuclei by two different criteria (p>0.05 and p>0.01). Stroma and Gleason grade 5 tissue yielded the most similar features, while Gleason grade 3 had the lowest number of similar features.