Skip to main content

Table 3 FVA results (simplex solvers) for ME76664 before and after lifting

From: Robust flux balance analysis of multiscale biochemical reaction networks

   Iterations   Infeasibilities
Flux Before After Before After
1 22510 44496 1.1×10−4 7.6×10−5
5001 30405 40318 1.5×10−4 9.6×10−5
10001 34963 41231 9.4×10−2 8.2×10−5
15001 103210 41891 4.5×10−5 9.4×10−6
20001 120089 40587 8.8×10−2 8.3×10−5
25001 30786 41161 1.7×10−4 8.3×10−5
30001 55177 40534 9.8×10−2 8.1×10−5
35001 68760 40933 1.3×10−4 8.3×10−5
40001 30360 40778 1.2×10−4 1.6×10−5
45001 107485 40905 3.1×10−5 8.3×10−5
50001 32553 40360 9.7×10−2 8.5×10−5
55001 20661 39909 9.5×10−5 5.7×10−5
60001 25477 39830 9.4×10−2 8.6×10−5
65001 139251 42230 2.9×10−5 8.4×10−5
70001 137611 42389 6.2×10−5 8.3×10−5
75001 40930 41139 4.0×10−5 8.2×10−5
  1. FVA results for the E. coli Metabolic-Expression model ME76664 using the CPLEX simplex solvers. Iterations and sum of infeasibilities for dual simplex (default) before lifting and for primal simplex after lifting. The first column lists which variable is being maximized. Lifting helps the CPLEX simplex solvers.