Skip to main content

Table 2 Method performance. The results given in this table show the ability of the whole method to identify AS homologous events. The results in the second column correspond to our method, while those in the third column correspond to a simple control method in which no NN was utilised (see Methods section). Both methods have a high accuracy, but our procedure displays a better precision, related to its ability to discard wrong candidates.

From: A procedure for identifying homologous alternative splicing events

 

OUR METHOD

CONTROL METHOD

Accuracy

0.99 ± 0.00

0.96 ± 0.04

Precision

0.98 ± 0.01

0.73 ± 0.31

Sensitivity

0.93 ± 0.02

0.97 ± 0.01

Specificity

1.00 ± 0.00

0.96 ± 0.05