Skip to main content

Table 1 the peak extraction accuracy. For both peak missing rate and area loss rate, the lower the better

From: A general-purpose signal processing algorithm for biological profiles using only first-order derivative information

Testing NumberMethod
DPAWaveletEMD
peak missing ratearea loss ratepeak missing ratearea loss ratepeak missing ratearea loss rate
10.00%7.29%0.00%15.74%0.00%11.82%
20.00%9.86%0.00%15.29%0.00%12.09%
30.00%13.47%0.00%21.04%0.00%19.25%
40.00%17.20%10.71%13.76%3.57%19.18%
50.00%15.68%0.00%36.56%0.00%9.27%
60.00%19.16%0.00%26.74%0.00%19.07%
73.45%2.57%0.00%19.55%0.00%24.07%
80.00%3.13%0.00%26.02%18.18%17.21%
90.00%8.62%0.00%36.43%0.00%36.02%
100.00%4.72%0.00%35.12%0.00%28.44%
110.00%11.26%0.00%47.87%0.00%16.22%
120.00%3.60%0.00%44.72%0.00%8.37%
130.00%9.21%0.00%39.72%0.00%15.70%
140.00%8.78%3.33%35.35%0.00%10.60%
150.00%6.83%0.00%16.24%0.00%38.08%