Skip to main content

Table 1 the peak extraction accuracy. For both peak missing rate and area loss rate, the lower the better

From: A general-purpose signal processing algorithm for biological profiles using only first-order derivative information

Testing Number

Method

DPA

Wavelet

EMD

peak missing rate

area loss rate

peak missing rate

area loss rate

peak missing rate

area loss rate

1

0.00%

7.29%

0.00%

15.74%

0.00%

11.82%

2

0.00%

9.86%

0.00%

15.29%

0.00%

12.09%

3

0.00%

13.47%

0.00%

21.04%

0.00%

19.25%

4

0.00%

17.20%

10.71%

13.76%

3.57%

19.18%

5

0.00%

15.68%

0.00%

36.56%

0.00%

9.27%

6

0.00%

19.16%

0.00%

26.74%

0.00%

19.07%

7

3.45%

2.57%

0.00%

19.55%

0.00%

24.07%

8

0.00%

3.13%

0.00%

26.02%

18.18%

17.21%

9

0.00%

8.62%

0.00%

36.43%

0.00%

36.02%

10

0.00%

4.72%

0.00%

35.12%

0.00%

28.44%

11

0.00%

11.26%

0.00%

47.87%

0.00%

16.22%

12

0.00%

3.60%

0.00%

44.72%

0.00%

8.37%

13

0.00%

9.21%

0.00%

39.72%

0.00%

15.70%

14

0.00%

8.78%

3.33%

35.35%

0.00%

10.60%

15

0.00%

6.83%

0.00%

16.24%

0.00%

38.08%