Skip to main content

Table 5 Parameters of large PP designs

From: Effective matrix designs for COVID-19 group testing

q

N

k

d

M

G

4*

1000

1

5

20

50.0

11

1000

5

3

121

8.3

32*

1000

10

2

352

2.8

32*

1000

25

2

832

1.2

53

1000

50

2

2703

0.4

5

5000

1

6

30

166.7

19

5000

5

3

209

23.9

23

5000

10

3

483

10.4

71

5000

25

2

1846

2.7

71

5000

50

2

3621

1.4

5

15000

1

6

30

500.0

16*

15000

5

4

256

58.6

25*

15000

10

3

525

28.6

53

15000

25

3

2703

5.5

125*

15000

50

2

6375

2.4

8*

25000

1

5

40

625.0

16*

25000

5

4

256

97.7

31

25000

10

3

651

38.4

53

25000

25

3

2703

9.2

163

25000

50

2

8313

3.0

  1. Designs and parameters for increasing sample numbers N for the detection of up to \(k \in \{ 1,5,10,25,50\}\) positives
  2. *Design based on prime power order \(q = p^n\)