Skip to main content

Table 3 Statistics of the fluorescent reagent based manual counts for the determination of the reference viability of the cultures that have been kept for a long time

From: A machine vision system for automated non-invasive assessment of cell viability via dark field microscopy, wavelet feature selection and classification

count #

k1

k2

 

#live

#dead

%live

#live

#dead

%live

1

67

17

79.8

55

14

79.7

2

86

27

76.1

113

27

80.7

3

89

14

86.4

66

13

83.5

4

98

28

77.8

86

21

80.4

5

126

20

86.3

89

14

86.4

6

96

33

74.4

136

27

83.4

7

126

34

78.8

75

21

78.1

8

73

16

82.0

80

7

92.0

9

95

29

76.6

48

11

81.4

10

104

25

80.6

62

13

82.7

  

mean

79.9

 

mean

82.8

  

SD*

4.1

 

SD*

4.0

  1. *SD: standard Deviation