Skip to main content

Table 2 Comparison of intra-sentence and cross-sentence extraction on the development data

From: Unsupervised inference of implicit biomedical events using context triggers

Gold intra-sentence events only

 

Gold

Predicted

Correct

Precision

Recall

F1

Intra

165

165

165

100.0

100.0

100.0

Cross

58

0

0

0.0

0.0

0.0

All

223

165

165

100.0

74.0

85.1

Gold intra-sentence events + our cross-sentence extraction

 

Gold

Predicted

Correct

Precision

Recall

F1

Intra

165

165

165

100.0

100.0

100.0

Cross

58

40

17

42.5

29.3

34.7

All

223

205

182

88.8

81.6

85.0

Our intra-sentence extraction only

 

Gold

Predicted

Correct

Precision

Recall

F1

Intra

165

325

153

47.1

92.7

62.4

Cross

58

0

0

0.0

0.0

0.0

All

223

325

153

47.1

68.6

55.8

Our intra-sentence & cross-sentence extraction

 

Gold

Predicted

Correct

Precision

Recall

F1

Intra

165

325

153

47.1

92.7

62.4

Cross

58

47

20

42.6

34.5

38.1

All

223

372

173

46.5

77.6

58.2