Skip to main content

Table 3 Results on NCBI catalogs

From: MALVIRUS: an integrated application for viral variant analysis

Pipeline

\(min_{lin}\)

\(max_{lin}\)

MALVIRUS

bcftools

lofreq

   

Precision

Recall

Precision

Recall

Precision

Recall

A

20

50

.951

.919

.909

.932

.778

.856

B

20

50

.972

.955

.921

.909

.788

.823

A

50

100

.951

.924

.907

.931

.757

.856

B

50

100

.967

.959

.916

.909

.763

.821

A

100

100

.952

.924

.908

.932

.738

.857

B

100

100

.968

.962

.916

.909

.744

.822

  1. For each catalog, we report the precision and recall achieved by MALVIRUS, BCFtools, and lofreq in calling the variations available in the catalog. The results are shown in terms of average over all the 41 considered samples. We highlighted in bold the best results. We considered 6 different catalogs built using pipeline A or B on the set of assemblies retrieved from NCBI, prefiltered using \(\tau _N = 1\%\) and then subsampled using different combinations of parameters \(min_{lin}\) and \(max_{lin}\)