Skip to main content

Erratum to: ‘Aro: a machine learning approach to identifying single molecules and estimating classification error in fluorescence microscopy images’

The Original Article was published on 27 March 2015

Unfortunately, the original version of this article [1] contained an error which is detailed below.

We had compared Aro to two published methods for identifying smFISH transcripts – threshold-picking [2] and FISH-quant [3]. The authors of FISH-quant were able to demonstrate that FISH-quant can perform substantially better than we were able to show. A revised fig. 5b (Fig. 1) shows the new FISH-quant results in green. Although it undercounts at high spot numbers compared to manual curation, it is far more reliable than we had shown, and any undercounting could be straightforwardly corrected.

Figure 5b (below). Comparison of spot identification and classification methods. B. A plot of manually counted spot number (x-axis) and estimated spot number (y-axis) by Aro, threshold-picking, and FISH-Quant across 28 C. elegans embryos. Both FISH-Quant and threshold-picking tend to underestimate the true number of spots (particularly at higher spot counts) while our Aro machine learning method performs well across a range of spots numbers. Spearman correlations (r) between the true and estimated spot number are listed for each method. All three techniques perform significantly better than random on this dataset. Aro and FISH-quant results are highly correlated with the manual count, and FISH-quant undercounting could be easily corrected by an appropriate factor. Interval estimates are depicted for Aro. Neither FISH-Quant nor threshold-picking provides a way to estimate error.

Fig. 1
figure 1

Comparison of spot identification and classification methods

Reference

  1. Wu AC-Y, Rifkin SA. Aro: a machine learning approach to identifying single molecules and estimating classification error in fluorescence microscopy images. BMC Bioinformatics. 2015;16:102.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Raj A, Rifkin SA, Andersen E, van Oudenaarden A: Variability in gene expression underlies incomplete penetrance. Nature. 2010;463:913–918.

  3. Mueller F, Senecal A, Tantale K, Marie-Nelly H, Ly N, Collin O, Basyuk E, Bertrand E, Darzacq X, Zimmer C: FISH-quant: automatic counting of transcripts in 3D FISH images. Nat Meth. 2013;10:277–278.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Scott A. Rifkin.

Additional information

The online version of the original article can be found under doi:10.1186/s12859-015-0534-z.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wu, A.CY., Rifkin, S.A. Erratum to: ‘Aro: a machine learning approach to identifying single molecules and estimating classification error in fluorescence microscopy images’. BMC Bioinformatics 17, 207 (2016). https://doi.org/10.1186/s12859-016-1049-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12859-016-1049-y