Skip to main content

Correction to: Auto3DCryoMap: an automated particle alignment approach for 3D cryo-EM density map reconstruction

The Original Article was published on 28 December 2020

Correction to: BMC Bioinformatics 2020, 21(Suppl 21):534 https://doi.org/10.1186/s12859-020-03885-9

Following publication of the original article [1], the authors received valuable feedback from readers in the field regarding our paper that was published in a special issue of BMC Bioinformatics in 2020 (BMC Bioinformatics, 21(S21):534, 2020), we discovered some visualization errors and typos in two Figures (Figs. 17 and 18) in the published manuscript. The Fourier Shell Correlation (FSC) values in Figs. 17b and 18b in the published paper were plotted in the incorrect order by mistake. The error only occurred in visualizing the data, while the original raw data are still the same as before. Therefore, we replot the data to create a new version of Figs. 17 and 18 and fix some typos (e.g., the title of the x-axis of Figs. 17b and 18b) according to the feedback. Figures 17 and 18 are given below.

Fig. 17
figure 17

Top and side-view molecular structural analysis using the KLH dataset. a Particles picking from a KLH micrograph using DeepCryoPicker [10]. b Fourier shell correlation plots for the final 3D reconstruction. The red curve is based on using the RELION 3.1 [8], the blue is based on using Auto3DCryoMap, and the green one is based on using EMAN 2.31 [7]. The average resolution of our 3D density map reconstruction using Auto3DcryoMap is ~ 2.19 Å, whereas that one generated from RELION 3.1 is ~ 2.215 Å and EMAN2 2.31 is ~ 4.378 Å. c Summary of particle selection and structural analysis. d The preprocessed versions of the original top and side and top-view particles that are used to generate the 3D density map structure. e, f Top and side views of the KLH 3D density reconstruction obtained with Auto3DCryoMap respectively

Fig. 18
figure 18

Top-view molecular structural analysis using the Apoferritin dataset. a Particles picking from the Apoferritin micrograph using DeepCryoPicker [10]. b Fourier shell correlation plots for the final 3D reconstruction. The red curve is based on using the RELION 3.1 [8], the blue is based on using Auto3DCryoMap, and the green one is based on using EMAN 2.31 [7]. The average resolution of our 3D density map reconstruction using Auto3DcryoMap is ~ 2.4 Å, whereas that one generated from RELION is ~ 2.75 Å and EMAN 2.31 is ~ 3.51 Å. c Summary of particle selection and structural analysis. d The preprocessed versions of the top-view particles that are used to generate the 3D density map structure. e 3D density map reconstruction of Apoferritin top-view protein that is obtained by the Auto3DCryoMap

Reference

  1. Al-Azzawi A, Ouadou A, Duan Y, et al. Auto3DCryoMap: an automated particle alignment approach for 3D cryo-EM density map reconstruction. BMC Bioinformatics. 2020;21:534. https://doi.org/10.1186/s12859-020-03885-9.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jianlin Cheng.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Al-Azzawi, A., Ouadou, A., Duan, Y. et al. Correction to: Auto3DCryoMap: an automated particle alignment approach for 3D cryo-EM density map reconstruction. BMC Bioinformatics 23, 92 (2022). https://doi.org/10.1186/s12859-022-04630-0

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/s12859-022-04630-0